cavity shaftwall systems national gypsum

BRAND 1Fire-Shield ShaftlinerXP

application details for I-Stud Cavity Shaftwall Systems, H-Stud Area Separation Wall Systems or other fire-rated designs shown in National Gypsum Company''s Gypsum Construction Guide. Gold Bond® BRAND 1"Fire-Shield® Shaftliner XP® 110924 Rev. 5/07 Technical Data Corporate Headquarters National Gypsum Company 2001 Rexford Road Charlotte, NC ...

Contact us

SHAFTWALL / AREA SEPARATION WALL product catalog

water, fresh air and exhaust systems intact when a fire occurs. CONSTRUCTION METHODS Cavity shaftwalls are constructed utilizing one of two methods: masonry/CMU or light-gauge steel and gypsum. Gypsum drywall shaftwall construction has become the preferred and most widely used method of construction for shaftwalls.

Contact us

Horizontal Shaftwall Duct and Ceiling Assemblies 09 21 16 ...

136 cavity shaftwall systems section 09 21 16.23 shaftwall systems the following paragraphs are for insertion into sections of generic specifications or generic/proprietary specifications covering shaftwall products.the national gypsum company product name follows the generic description in parentheses.

Contact us

ShaftWall is a Fire resistant shaft and duct encasement system

ShaftWall Shaft and duct encasement system. ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an …

Contact us

EXP SHAFTLINER (National Gypsum) | Free BIM object for ...

The panels are key components in the I-Stud, C-T Stud and C-H Stud Cavity Shaftwall Systems and the H-Stud Area Separation Fire Wall Systems. The Shaftliner is encased with a coated fiberglass mat with National Gypsum''s original PURPLE™ color which provides superior weather resistance capabilities.

Contact us

AECinfo News: A Short History Of High-Rise Cavity ...

 · The Cavity Shaftwall System is typically installed using 1-inch-thick gypsum shaftliner panels inside a minimum 2-1/2-inch metal structural framing with an integral space to hold the panels in place on the shaft side. Metal J-track runners are placed horizontally on the top and bottom and vertically at partition ends. They also frame openings.

Contact us

FIRE-SHIELD SHAFTLINER XP (National Gypsum) | Free BIM ...

The panels are key components in the I-Stud, C-T Stud and C-H Stud Cavity Shaftwall Systems and the H-Stud Area Separation Fire Wall Systems. Shaftliner XP is designed to provide extra protection against mold and mildew compared to standard Shaftliner products. Shaftliner XP is easily identified by National Gypsum''s original PURPLE™ color.

Contact us

Cavity Shaft Wall System

The Cavity Shaft Wall System includes components that provide the strength to withstand lateral loads and fire protection necessary for walls that enclose elevator shafts, stairwells and other vertical shafts. The system includes gypsum liner panels, gypsum panels and cement board, interior finishing products and framing components.

Contact us

ShaftWall

ShaftWall (C05 S02) Shaft and duct encasement system. ShaftWall provides a lightweight, fire resistant structure to protect elements in confined spaces wherever access is limited to one side only. The system provides a protective structure which can be incorporated at an early stage of the construction without the need for scaffolding.

Contact us

1 in x 2 ft x 8 ft 10 in National Gypsum Gold Bond BRAND ...

Treated fiberglass facer and gypsum core provide extra protection against mold growth per ASTM D 3273, achieving a score of 10, the best possible score. eXP Shaftliner can be substituted for National Gypsum''s Gold Bond BRAND Shaftliners in Cavity Shaftwall, Area Separation Fire Wall Systems and solid laminated partitions.

Contact us

Submittal Sheet Shaftwall Insulation

in the cavity of a metal stud and gypsum board shaftwall partition system. Shaftwall Insulation reduces the amount of airborne sound transmitted through the shaftwall to the adjoining space. Depending on the construction method used, Shaftwall Insulation can reduce the amount of airborne sound transmitted through a shaftwall by as much as 5 to ...

Contact us

Section 09 29 00

 · System: Georgia-Pacific Gypsum LLC''s "Series 627 (Two Hour) Shaftwall System"; National Gypsum Co.''s "Gold Bond I-Stud Cavity Shaftwall System"; or equal. Fire Rating: Two hours. Metal Components: J-runners, C-channels, and C-H studs; hot-dip galvanized steel, sizes and types as recommended by system manufacturer.

Contact us

Shaft Liner submittaL

American Gypsum''s Shaft Liner has been approved for use in the following assemblies: U 375 2 Hour H-Stud Area Separation Wall System V 455 1 & 2 Hour Shaftwall Systems using I, C-H and C-T Studs U 428 2 Hour Shaftwall System using C-H and C-T Studs U 429 2 Hour Area Separation Wall System using C-H and C-T Studs V 433 2 Hour Shaftwall System ...

Contact us

GA

The Gypsum Association FIRE RESISTANCE DESIGN MANUAL is referenced by the following code and standards writing organizations: INTERNATIONAL BUILDING CODE, published by: International Code Council, Inc. 5203 Leesburg Pike, Suite 600 Falls Church, ia 22041 (See footnote a, Tables 719.1a, 719.1b, and 719.1c) BOCA NATIONAL BUILDING CODE ...

Contact us

Gypframe Angle GA3

Key facts GA3 – 38mm x 19mm angle used in the jointing process of Gyproc CoreBoard in ShaftWall systems. Application Steel angle used for reinforcing horizontal joints in CoreBoard. Used in the Gyproc

Contact us

GOLD BOND BRAND 1 FIRE-SHIELD SHAFTLINER XP

ed for National Gypsum''s Gold Bond BRAND Fire Shield Shaftliner in Cavity Shaftwall, Area Separation Wall Systems and solid laminated partitions. MOLD AND MILDEW RESISTANCE Shaftliner XP was designed to provide extra protection against mold and mildew. When tested by an independent lab per ASTM D3273 ("Standard Test Method for Resistance to

Contact us

Technical Services: 888-437-3244 Sales: 800-543-7140 ...

4" 20ga ClarkDietrich Shaftwall System ClarkDietrich CT Cavity Shaftwall System ClarkDietrich CT Cavity Shaftwall Studs are high-performance members engineered to maintain shaftwall integrity. CT Studs are designed for use with 1" thick gypsum 24" wide liner panels. Gypsum liner panels are inserted into the "T" portion of the stud and are ...

Contact us

Dietrich Shaftwall Stairwall

System consists of 1" shaftliner panels supported by 2-1/2", 4" or 6" CT-Studs and faced on one side with two layers of 1/2" proprietary fire code board. Shaftwall Designed to enclose stairwalls, this system is finished on both sides with a single layer of 1/2" proprietary fire code board. Stairwall DMF C-T Stud Nominal Design Weight Areas lx ...

Contact us

Shaftwall Systems | Gold Bond® Building Products

Accelerate installation on every project. Entering elevator shafts to install shaftwall systems can make installation slower and more complicated for crews of all experience levels. Gold Bond® Shaftliners offer an efficient installation from the ground that avoids the need to enter the shaft. Dimensionally stable under changes in temperature ...

Contact us

Shaft wall Systems National Gypsum by Macopa

 · The 3" leg, nominal 20 gauge J Track shall be used at the juncture of the elevator door frame and the Cavity Shaftwall System. See drawings on pages 128 and 129 for details.

Contact us

12TH EDITION National Gypsum Construction Guide

Cavity Shaftwall Systems.....123 Horizontal Shaftwall Duct and Ceiling Assemblies.....137 H-Stud Area Separation Wall System.....139 PermaBase® BRAND Cement Board ... Before National Gypsum releases a system to the build-ing industry, the sys-

Contact us

I Stud Cavity Shaftwall System for Horizontal Duct ...

Project Name/Project Number/30-Sep-13 4 09 21 16.23 Shaftwall Systems National Gypsum Company d. Edges: Square, Tapered, or Beveled Taper (Sta-Smooth Edge). 5. Fire-Rated Mold-Resistant Gypsum Board: A gypsum core wall panel with additives to enhance fire resistance of the core and the water resistance of the core; surfaced with

Contact us

BRAND 1Fire-Shield ShaftlinerXP

application details for I-Stud Cavity Shaftwall Systems, H-Stud Area Separation Wall Systems or other fire-rated designs shown in National Gypsum Company''s Gypsum Construction Guide. Gold Bond® BRAND 1"Fire-Shield® Shaftliner XP® 110924 Rev. 9/05 Technical Data Corporate Headquarters National Gypsum Company 2001 Rexford Road Charlotte, NC ...

Contact us

Cavity Shaftwall Systems

The Cavity Shaftwall Systems were developed to enclose elevator shafts and other vertical chases in buildings where it is advantageous to erect these walls from one side only and where fire resistance and resistance to air pressures are required. National Gypsum Company Cavity Shaftwall Systems may be constructed with C-T, C-H or I-Stud ...

Contact us

Shaftwall

Shaftwall. 4. One layer 1″ x 24″ (25.4 mm) ToughRock® Shaftliner or DensGlass® Shaftliner panel inserted between 2-1/2″ floor and ceiling runners of 2-1/2″ steel C-T, C-H studs. Opposite side: Base layer of 5/8″ (15.9 mm) ToughRock® Fireguard X® Products or 2/8″ (15.9 mm) DensArmor Plus® Fireguard® gypsum panels installed ...

Contact us

Technical Guide: Shaftwall/Stairwell Systems (DensGlass ...

Georgia-Pacifi c Gypsum shaftwall/stairwell systems conform to the requirements of the IBC which now contain the addition of ... The 2-1/2" (64 mm) stud provides a 1-1/2"(38 mm) air cavity for services. Studs are friction-fitted between top and bottom J tracks. Use J tracks for all closure details, including duct and door openings ...

Contact us

WARE''s NEW Shaftwall and Area Separation Wall Systems

1" gypsum liner board ANYUL Classified 1/2"Type C or 5/8"Type X gypsum wallboard Both the MARINOWARE CT-Stud Shaftwall and H-Stud Area Separation Wall Systems are approved with all UL-listed gypsum board manufacturers including United States Gypsum, National Gypsum, Georgia-Pacific, Lafarge Gypsum, James Hardie, BPB, PABCO, Temple, Eagle ...

Contact us

Fire retardant shaft wall

NATIONAL GYPSUM COMPANY . Primary Class: 52/30. Other Classes: 52/236.7, 52/481.1, 52/781 ... CAVITY SHAFT WALL: 1972-11-07: Balinski: 3034609: Building partition structure: 1962-05-15: Young: ... This invention relates to an elevator shaft wall of gypsum boards affixed to vertically disposed lightweight metal studs, particularly studs having a ...

Contact us

The Basics of Acoustics and Sound Control – Gypsum Association

Face layer 5/8" Type X gypsum wallboard applied parallel to each side with 1-5/16" Type S drywall screws 12" o.c. Joints staggered 24" each layer and each side. Sound tested with 1-1/2" mineral fiber insulation, 3.0 pcf, friction fit in stud space. Test reference: CK 684-14. System 4 …

Contact us

º INSTALLATION GOLD BOND CAVITY SHAFTWALL SYSTEM ...

Cavity Shaftwall systems are a nonload-bearing drywall parti-tion made up of two basic components: gypsum board and metal framing. Gypsum board includes 1" Fire-Shield Shaftliner or 1" Fire-Shield Shaftliner XP panels, 1/2" Fire-Shield C and 5/8" Fire-Shield gypsum board face panels. 1/2" XP Fire-Shield C or 5/8" XP Fire-Shield gypsum board

Contact us

Gold Bond® eXP® Shaftliner | Mold & Mildew Resistant ...

Use eXP® Shaftliner to construct lightweight fire barriers for cavity shaftwalls (1-4 hr.) and area separation fire walls (2 hr.). eXP® Shaftliner consists of a moisture- and mold resistant gypsum core encased in a coated, specially designed PURPLE® fiberglass mat on the face, back and sides. It is available in a Type X core.

Contact us

Frequently Asked Questions (FAQs) – Gypsum Association

Again, for gypsum board in non-exposed rooms, a judgment call by a specialist should determine the extent, if any, of replacement. However, fires also result in exposure to smoke and water. Water is the easiest to assess. First, it is critical to determine if the studs and other materials in the wall cavity are dry and undamaged.

Contact us